Publications

Timed synchronization of muscle contraction to heart beat enhances muscle hyperemia  (2020)

Authors:
Giuriato, Gaia; Ives, Stephen J; Tarperi, Cantor; Bortolan, Lorenzo; Ruzzante, Federico; Pedrinolla, Anna; Martignon, Camilla; Laginestra, Fabio Giuseppe; Cevese, Antonio; Schena, Federico F; Venturelli, Massimo
Title:
Timed synchronization of muscle contraction to heart beat enhances muscle hyperemia
Year:
2020
Type of item:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Language:
Inglese
Format:
A Stampa
Referee:
Name of journal:
JOURNAL OF APPLIED PHYSIOLOGY
ISSN of journal:
8750-7587
N° Volume:
128
Number or Folder:
4
:
American Physiological Society:9650 Rockville Pike:Bethesda, MD 20814:(301)530-7180, EMAIL: subscrip@the-aps.org, INTERNET: http://www.the-aps.org, Fax: (301)571-8313
Page numbers:
805-812
Keyword:
Blood flow; Electrical stimulation; Muscle circulation; Vascular conductance; muscle contraction
Short description of contents:
Blood flow (BF) to exercising muscles is susceptible to variations of intensity, and duration of skeletal muscle contractions, cardiac cycle, blood velocity, and vessel dilation. During cyclic muscle activity, these elements may change proportionally with or without direct optimal temporal alignment, likely influencing BF to active muscle. Ideally, the pulsed delivery of blood to active muscle timed with the inactive phase of muscle duty-cycle would enhance the peak and average BF. To investigate the phenomenon of muscle contraction and pulse synchronicity, electrically-evoked muscle contractions (trains of 20Hz, 200ms duration) were synchronized with each systolic phase of the blood velocity spectrum (aBVS). Specifically, unilateral quadriceps contractions matched in-phase (IP) with the aBVS were compared to contractions matched out of phase (OP) with the aBVS in 10 healthy participants (26±3 years). During each trial, femoral BF of the contracting limb and central hemodynamics were recorded for 5 minutes with an ultrasound doppler, a plethysmograph, and a cardioimpedence device. At steady-state (5th min) IP BF (454±30 mL/min), MAP (113±3 mmHg) and vascular conductance (4.3±0.2 mL/min/mmHg) were significantly lower (all, P<0.001) in comparison to OP BF (784±25 mL/min), MAP (108±2 mmHg) and vascular conductance (6.7±0.2 mL/min/mmHg). On the contrary, no significant difference (all, P>0.05) was observed between IP and OP central hemodynamics (HR:79±10 vs. 76±11 bpm, CO:8.0±1.6 vs. 7.3±1.6 L/min) and ventilatory patterns (VE:14±2 vs. 14±1 L/min, VO2:421±70 vs. 397±34 mL/min). The results suggest that muscle contractions occurring during OP and that do not interfere with aBVS elicit a maximization of muscle functional hyperemia.
Web page:
https://doi.org/10.1152/japplphysiol.00898.2019
Product ID:
113548
Handle IRIS:
11562/1014060
Last Modified:
November 15, 2022
Bibliographic citation:
Giuriato, Gaia; Ives, Stephen J; Tarperi, Cantor; Bortolan, Lorenzo; Ruzzante, Federico; Pedrinolla, Anna; Martignon, Camilla; Laginestra, Fabio Giuseppe; Cevese, Antonio; Schena, Federico F; Venturelli, Massimo, Timed synchronization of muscle contraction to heart beat enhances muscle hyperemia «JOURNAL OF APPLIED PHYSIOLOGY» , vol. 128 , n. 42020pp. 805-812

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS

<<back

Activities

Research facilities

Share