Pubblicazioni

Reliability of TMS phosphene threshold estimation: Toward a standardized protocol  (2017)

Autori:
Mazzi, Chiara; Savazzi, Silvia; Abrahamyan, Arman; Ruzzoli, Manuela
Titolo:
Reliability of TMS phosphene threshold estimation: Toward a standardized protocol
Anno:
2017
Tipologia prodotto:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Lingua:
Inglese
Formato:
A Stampa
Referee:
Nome rivista:
BRAIN STIMULATION
ISSN Rivista:
1935-861X
N° Volume:
10
Numero o Fascicolo:
3
Intervallo pagine:
609-617
Parole chiave:
phosphene threshold; psychophysics; transcranial magnetic stimulation (TMS); vision
Breve descrizione dei contenuti:
BACKGROUND: Phosphenes induced by transcranial magnetic stimulation (TMS) are a subjectively described visual phenomenon employed in basic and clinical research as index of the excitability of retinotopically organized areas in the brain. OBJECTIVE: Phosphene threshold estimation is a preliminary step in many TMS experiments in visual cognition for setting the appropriate level of TMS doses; however, the lack of a direct comparison of the available methods for phosphene threshold estimation leaves unsolved the reliability of those methods in setting TMS doses. The present work aims at fulfilling this gap. METHODS: We compared the most common methods for phosphene threshold calculation, namely the Method of Constant Stimuli (MOCS), the Modified Binary Search (MOBS) and the Rapid Estimation of Phosphene Threshold (REPT). In two experiments we tested the reliability of PT estimation under each of the three methods, considering the day of administration, participants' expertise in phosphene perception and the sensitivity of each method to the initial values used for the threshold calculation. RESULTS: We found that MOCS and REPT have comparable reliability when estimating phosphene thresholds, while MOBS estimations appear less stable. CONCLUSIONS: Based on our results, researchers and clinicians can estimate phosphene threshold according to MOCS or REPT equally reliably, depending on their specific investigation goals. We suggest several important factors for consideration when calculating phosphene thresholds and describe strategies to adopt in experimental procedures.
Pagina Web:
https://dx.doi.org/10.1016/j.brs.2017.01.582
Id prodotto:
97059
Handle IRIS:
11562/960719
ultima modifica:
11 novembre 2022
Citazione bibliografica:
Mazzi, Chiara; Savazzi, Silvia; Abrahamyan, Arman; Ruzzoli, Manuela, Reliability of TMS phosphene threshold estimation: Toward a standardized protocol «BRAIN STIMULATION» , vol. 10 , n. 32017pp. 609-617

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS

<<indietro

Attività

Strutture

Condividi